Condensation and mould risk calculator.
Enter the temperature and humidity in your room, from a cheap digital hygrometer, and the temperature outside. The calculator works out the dew point and estimates which windows and walls will run with condensation or stay damp enough for mould, using the method UK building standards use (BS EN ISO 13788).
Your readings
Enter a room humidity between 1 and 100%, and temperatures between -20 and 40°C.
Dew point:
Any surface in the room colder than this will get wet.
| Surface | Surface temp. | Humidity at surface | Result |
|---|---|---|---|
- To keep a solid-wall corner below the mould threshold at these temperatures, keep room humidity under .
- To stop condensation on older double glazing, keep it under .
- It's as warm or warmer outside than in, so these surfaces aren't being chilled.
How to take good readings
A digital hygrometer costs under £15 and is the single most useful thing you can own if you're fighting condensation. Put it on an inside wall at head height, away from the kettle, the shower and the window, and give it an hour to settle. Read it first thing in the morning, when bedrooms are most humid and walls are coldest. Use that night's outside temperature from a weather app.
What the results mean
Condensation means the surface is below the dew point: water forms on it. That's normal for a short time on a single-glazed window on a cold morning, and a problem when it runs down onto sills and frames every day.
Mould risk means the air touching the surface is at or above 80% relative humidity. Mould doesn't need running water. A wall that stays that damp for days at a time is enough. That's why mould appears in corners and behind wardrobes first. The air there moves less, so the surface runs colder.
What actually brings humidity down
- Run extractor fans while cooking and showering, and for a while afterwards. Building Regulations expect roughly 30 litres a second from a cooker hood and 15 litres a second from a bathroom fan. If yours barely moves a sheet of tissue, it isn't doing the job.
- Keep trickle vents open. They're designed to stay open in winter, and closing them is one of the commonest causes of bedroom mould.
- Dry washing outside, or in a room with the door shut and the window open or a dehumidifier running. A load of washing can release a couple of litres of water into the air.
- Keep heating low and steady rather than off and on. Cold walls are what turn ordinary humidity into condensation.
- Pull furniture a few centimetres off outside walls so air can reach them.
If the numbers still say "mould risk" at sensible humidity, the problem is the wall rather than the way you live: a cold bridge, missing insulation, or a wall that is damp from outside. That is when a survey is worth having. Landlords can't dismiss mould as a "lifestyle" problem: government guidance puts the responsibility for finding and fixing the cause on them.
Assumptions
The calculator uses typical U-values (how quickly heat escapes): single glazing 5.7, older double glazing 2.8, modern double glazing 1.4, a 225mm solid brick wall 2.1, an unfilled cavity wall 1.5 and an insulated wall 0.5 (W/m²K). It uses the standard internal surface resistances: 0.13 for open surfaces, 0.25 for corners and behind furniture. Real walls vary, frames and glass edges run colder than the centre of a pane, and mould risk is about conditions that last for days, not a single reading. Treat the results as a guide to where to look, not a diagnosis.
Not sure it's condensation at all? Try the rising damp checker, or read about condensation and mould.
Want someone to find the cause?
Book a free Thermal Damp Check
Usually the same week
What have you noticed?
Where should we call you?
Thanks, that's come through.
We'll call you within one working day to arrange your Thermal Damp Check. If it's urgent, call 07365 672153.